- A3
-
Beam lancherSUBMITDOWNLOAD
-
Low Headroom Single Girder Overhead CraneSUBMITDOWNLOAD
-
Magnet Double Girder Overhead CraneSUBMITDOWNLOAD
-
Insulation Double Girder Overhead CraneSUBMITDOWNLOAD
Motor and electrical appliances of this crane are explosion proof type. When explosion proof grade is ExdII CT4, travelling mechanism should do spark proof treatment. The whole machine meets standards of JB/T10219-2001 (Specification for explosion-proof cranes with electric wire rope hoist),explosion proof grade have ExdII BT4 and ExdII CT4 two kinds. It has characteristic of rational construction, perfect appeaance and strong Ex technical performace.
This product is suitable for areas where the explosion-transmission is not higher than IIB or IIC and the ignition temperature group of inflammable gas or explosive mixture of steam and gas is not lower than T4. Applicable dangerous zones are zone 1 and zone 2. (please refer to GB 3836.1-2000 for details).
It is generally controlled on the ground, but control from the driver' cabin is also allowable. The working grade is intermediate.
(Note: 5-10t crane does not have an auxiliary hook.)
Components:
Control method: Cabin control.
Explosion proof electronic hoist.
The decelerator, Motor are famous brand or other brand according to customer requirement.
Many electric elements are choosed under the customer required.
Feature:
High safty fator
Precision
Move and stop smoothly
Easily intall, maintain,dismantle
Parts and compent are easy to change when broken.
Competive price.
Conditions of Use:
1. Elevations less than 1000m.
2. Ambient air temperature does not exceed -20 ~ 40 degrees Celsius.
3. Ambient air relative humidity is not more than 85% (+25 degrees Celsius)
4. Indoor use (corrosive environment and outdoor areas, take special orders).
5.Five. Rated cycle of 10 minutes, the benchmark of 25% continuous power, the equivalent number of starts per hour, not more than 120 times.
6. Electric hoist the main circuit rated voltage up to AC 380V, rated frequency 50Hz, control circuit voltage 380V, 36V and 42V.
7. Apply when the plant specified in Table 1 within the flammable gas, vapor and air, an explosive mixture.
Safety:
Overload protection,
Main lifting motor with thermal protection,
Hooks with latch,
Rubber buffers,
Protective earthing,
Crane switch and travel end switch,
Emergency switch can stop all movement when any dangerous happened,
Sub-assemblies characteristic are tested before assemly.
This crane adapts to the environment in factory that have explosive gas formed by inflammable gas, steam and air of which explosion proof grade is less than B grade or C grade and ignition group is more than T4 (135℃)group. And the explosion proof electric hoist adapts to 1 area or 2 area, not 0 area.